Indian Farmers Fertilizers Cooperative Limited (IFFCO) runs an Ammonia and Urea plant at Kalol, Gujarat, producing 1,100 TPD of ammonia and 1,650 TPD of urea on the Ahmedabad-Mehsana State Highway. The urea control room sits inside this facility, exposed to ammonia in the surrounding atmosphere through doors, wall penetrations, and routine ingress and egress. IFFCO engaged iFluids Engineering to deliver the ammonia gas ingress control room pressurization design for this building: a system to hold the control room, instrument panel room, AHU room, engineering station room, and pantry at a positive pressure relative to the plant atmosphere outside, while neutralizing any ammonia that did enter. The same exposure exists at every ammonia and urea plant where a control building sits close to the process area, which makes this a recurring engineering problem across the global fertilizer and nitrogen chemicals sector, not a site-specific anomaly unique to Kalol.
| Field | Detail |
| Sector | Fertilizer Manufacturing (Ammonia and Urea) |
| Location | Kalol, Gandhinagar, Gujarat, India |
| Facility Type | Urea Control Building (two floors, existing operational plant) |
| Client | Indian Farmers Fertilizers Cooperative Limited (IFFCO) |
| Scope of Work | Detailed engineering for control room pressurization and ammonia neutralization |
| Standards Applied | Positive-pressure airlock design to maintain a non-hazardous atmosphere inside an occupied control building |
| Project Duration | Not publicly disclosed |
| iFluids Team Size | Not publicly disclosed |
The Engineering Challenge
iFluids inherited a control building with three existing 16.5 TR package AC units, routed supply and return ducts, and no barrier between its doors and an atmosphere that could carry ammonia whenever the plant was operating. The task was converting that exposure into a measured, contained system.
NIOSH sets 210 mg/m³ (300 ppm) as the Immediately Dangerous to Life or Health (IDLH) threshold for ammonia, the concentration above which a single uncontrolled exposure can incapacitate or kill. That threshold is why passive sealing, caulk, weatherstripping, better door gaskets, was never going to be sufficient for a control room where operators needed to work an entire shift without incident. The building had six doors across its ground and first floors (urea instrument panel room, package AC room, and AHU room below; urea control room, engineering station room, and pantry above), and every one of them was a potential ingress point every time someone walked through it.
Below the IDLH threshold, ammonia still carries a sharp, recognizable odor at concentrations as low as 5 ppm, so an operator inside an under-pressurized control room would register discomfort and eye or throat irritation well before any life-threatening exposure. That gave iFluids a secondary design constraint beyond pure survivability: the pressurization system had to hold concentrations low enough that operators never perceived ammonia at their workstations at all, since odor-driven evacuations and shift disruptions carry their own operational cost even when no one is harmed.
iFluids first studied the integrity of the existing structure. The team mapped every air leakage point across both floors and tied each one to a specific door, cutout, crack, or hole rather than treating the building as a single uncharacterized envelope. That inventory became the basis for the pressurization system design that followed, because you cannot size a blower or a duct run against a leakage path you have not located and quantified.
iFluids Approach and Methodology

iFluids designed a six-airlock pressurization and neutralization system, four on the ground floor and two on the first, intercepting ammonia before it reaches the building interior. The design routes 2,300 CFM of filtered air through a dry scrubber, holding 40 to 50 Pa of positive pressure across every airlock and the pantry.
This sequencing matters because control room pressurization sits inside a broader body of hazardous area classification practice: a positively pressurized, continuously monitored enclosure is one of the recognized ways to keep an otherwise classified or at-risk space treated as non-hazardous for electrical and occupancy purposes. iFluids applies that same positive-pressure logic across its hazardous area work, detailed further in Hazardous Area Classification Standards (IEC, ATEX, NEC, OISD), and the Kalol control building design follows the same underlying principle: pressurize first, monitor continuously, and treat every door as a managed boundary rather than a sealed one.
The methodology followed four engineering steps, in sequence:
- Airlock placement. iFluids positioned one airlock at every door identified in the leakage survey, four on the ground floor and two on the first floor, so no opening bypassed the pressurization boundary.
- Gas treatment selection. The team selected a dry scrubber over a wet scrubber for the neutralization stage, a decision covered in full in the next section, and positioned it upstream of the Double Skin Filter Unit and blower so incoming air is neutralized before it reaches the filtration stage.
- Duct routing. iFluids routed new ductwork from the dry scrubber through every airlock room and the pantry, sized to deliver the full 2,300 CFM without starving any single room of its share of filtered air.
- Pressure control and fire safety integration. Each airlock received a Volume Control Damper to hold its target pressure and a Fusible Fire Damper to isolate the room automatically in a fire event, plus Pressure Relief Dampers sized to each room’s air change rate so the system cannot over-pressurize and jam the doors shut.
This sequence is what separates a pressurization retrofit that works on a brownfield building from one that is sized on paper and fails in the field: the leakage survey drives the airlock count, the airlock count drives the duct sizing, and the duct sizing drives the blower and damper selection, in that order. Retrofitting an occupied, operating control building carries a constraint a new-build design never faces: the existing 16.5 TR package AC units, the already-routed supply and return ducts, and the building’s day-to-day occupancy all had to stay functional throughout the engineering and installation process, which is why the civil, structural, HVAC, and electrical work was scoped as four distinct execution packages rather than one combined contract.
Recognized for excellence.
PROJECTS DELIVERED ACROSS THE GLOBE
Technical Decisions and Engineering Rationale
iFluids recommended a dry scrubber in place of the more commonly specified wet scrubber for ammonia neutralization at Kalol, a decision that determined the chemical handling, maintenance, and corrosion profile of the entire system for the operating life of the control building.
| Wet Scrubber | Dry Scrubber |
| Neutralizes ammonia content up to 75-80% | Neutralizes ammonia content up to 99.9% at 2.5 ppm and 99.8% at 5,000 ppm |
| Uses sulphuric acid as the neutralizing chemical | Uses activated carbon media as the neutralizing agent |
| Generates toxic fumes from the sulphuric acid reaction, unsuitable for an occupied building | Generates no toxic byproducts from the carbon media |
| Sulphuric acid is corrosive to ducts and electrical components | Carbon media is non-corrosive to ducts and electrical components |
| Requires chemical dosing pumps, pH dosing pumps, and associated piping, valves, and instruments | Requires only blowers, ducts, and a filter housing for full operation |
| Lower rate of ammonia adsorption | Higher rate of ammonia adsorption |
A wet scrubber’s 75-80% neutralization ceiling left too wide a margin for a control room that had to stay occupied through every operating condition, and the sulphuric acid dosing system it requires introduces exactly the kind of corrosive, instrumented, maintenance-heavy equipment a control building is designed to avoid. The dry scrubber’s 99.9% neutralization rate at the lower 2.5 ppm concentration band, falling to a still-high 99.8% at the much more severe 5,000 ppm band, gave iFluids a system that holds its performance across both routine trace exposure and a worst-case release scenario without adding a single pump or dosing line to the building.
The decision also changes the building’s long-term maintenance profile. A wet scrubber’s sulphuric acid dosing pumps, pH dosing pumps, and connecting piping are wear items that need calibration, chemical replenishment, and corrosion inspection on a recurring schedule, and any one of those components failing degrades the neutralization rate below its rated 75-80% ceiling. A dry scrubber’s carbon media is replaced on a fixed interval rather than monitored and dosed continuously, which converts an ongoing instrumented maintenance task into a predictable consumable swap, a meaningful difference for a plant that wants the system to keep performing without a dedicated chemical-handling routine built around it.
Outcomes and Deliverables
iFluids delivered a fully specified pressurization and neutralization system: six airlocks, a dry scrubber train, 2,300 CFM of routed and filtered air, and a damper and control scheme covering pressure relief, volume control, and fire isolation across every room in the building.
| Deliverable | Mechanism | Outcome |
| Leakage Survey and Integrity Assessment | Door-by-door and opening-by-opening mapping of both floors | Identified every ingress point driving the airlock count and placement |
| Airlock Pressurization Design | Six airlocks (4 ground floor, 2 first floor), Volume Control Dampers | Holds 40-50 Pa positive pressure across all airlock rooms and the pantry |
| Dry Scrubber Neutralization System | Activated carbon media, positioned upstream of the Double Skin Filter Unit and blower | 99.9% ammonia neutralization at 2.5 ppm, 99.8% at 5,000 ppm |
| Fire and Pressure Safety Integration | Fusible Fire Dampers and Pressure Relief Dampers sized to each room’s CFM | Automatic fire isolation and over-pressure protection without manual intervention |
In engineering terms, the building moved from an uncharacterized set of leakage paths to a quantified, 2,300 CFM pressurization system that holds a defined pressure band under normal operation and isolates automatically under fire or over-pressure conditions. In business terms, IFFCO gained a control building its operators can occupy through every plant operating state without relying on sulphuric acid dosing equipment or its associated maintenance burden, and without the schedule risk of a chemical dosing system that needs its own permitting and handling procedures before commissioning.
Lessons and Applicability
The core lesson generalizes beyond one urea control room: a pressurization system sized from a documented leakage survey outperforms one sized from a generic air-change allowance, and a dry scrubber outperforms a wet scrubber wherever a building must stay occupied through a worst-case gas release.
Any ammonia, urea, or fertilizer facility with a control building adjacent to process equipment faces the same underlying problem iFluids solved at Kalol: doors and openings that connect an occupied space to a potentially hazardous atmosphere. Facilities across GCC, India, and Southeast Asia running similar ammonia refrigeration, urea synthesis, or nitrogen fertilizer processes carry the same exposure, often with control buildings designed decades before the plant’s current throughput and leak-path profile were established. The same four-step methodology, survey the leakage, select the neutralization technology against worst-case concentration bands rather than average exposure, route ducting to match the airlock count, and integrate pressure relief with fire safety, applies directly to any brownfield control building retrofit facing ammonia, H2S, or similar toxic gas ingress risk.
It also transfers across project phase, not just across geography. A facility commissioning a new control building can apply the same leakage-survey-first logic at the design stage, before any duct is routed, while a facility with an aging building retrofitted decades ago can apply it exactly as iFluids did here: survey what exists, quantify the leakage, and size the pressurization and neutralization system against that survey rather than against the original design intent, which rarely matches current plant throughput or current door and penetration counts.
Conclusion and Next Steps
iFluids Engineering converted an exposed urea control building at IFFCO’s Kalol facility into a positively pressurized, dry-scrubber-neutralized workspace, sized from a documented leakage survey rather than a generic allowance. The underlying methodology, airlock placement driven by a leakage survey, neutralization technology selected against worst-case concentration bands, and pressure relief integrated with fire safety, applies to any ammonia, urea, or fertilizer facility with an occupied control building exposed to process-area atmosphere. For the related assessment-phase work on this same building, see Assessment of Safety of Control Rooms: Installation of a Suitable Pressurizing System at the Urea Control Room. iFluids delivers this work under its Smoke and Gas Ingress Analysis (SGIA) service line for control buildings, accommodation modules, and occupied spaces across the GCC, India, and Southeast Asia.
If your facility has a control room, substation, or occupied building exposed to ammonia, H2S, or another toxic gas release, contact iFluids Engineering to discuss a leakage survey and pressurization design for your specific building.